<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-27 19-11-38
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
96.90 MHz 4/5, 50 dBuV VOLTAGE
Pilot RDS Phase Difference
7.1 kHz 3.5 kHz 20 deg
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 0,0 kHz
MIN Hold Max. Samples at Total Samples % above 75,0 kHz
14 kHz 73 kHz 7377 66,2871
Modulation Power
Limit Measuring Tolerance
10,0 dBr 0,0 dBr
MIN AVE MAX % above 10,0 dBr
7,5 dBr 8,25 dBr 8,9 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"VOLTAGE " FE45 10 (Pop M) 1 0 0 5 19:11, 27.12.2024
RT
"VOLTAGE - Dance music "
AF EON
96.9, 102.9 MHz -
FM Scope Station: 96.90 MHz, signal: 4/5 (49 dBuV) Max at: 73 kHz MIN: 14 kHz % above 75 kHz: 66,2871 Acquired: 2024/12/27 19:10:34 Total samples: 7377 Equivalent time: 0:06:08 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 8,9 dBr MIN: 7,5 dBr AVE: 8,25 dBr % above 10,0 dBr: 0,0 Last value: 7,6 dBr (2024/12/27 19:10:33) Station: 96.90 MHz, signal: 4/5 (49 dBuV) 19:04 19:05 19:06 19:07 19:08 19:09 19:10 0 50 100 Dev. MAX [kHz] 0 5 Pm [dBr] 0 5 Signal Quality